|
 |
|
 |
|
|
|
System Includes: |
|
Indoor Unit - Air Handler
Outdoor Unit - Compressor
Digital, Multi-function LCD Remote Control
Installation Kit + Product Manuals
Washable Screen - Activated Carbon Filters |
|
|
|
|
|
|
|
 |
Top Line Features: |
20.5 SEER - 11.8 HSPF - AHRI CERTIFIED
Pre-Charged w/ Eco-friendly R410A Refrigerant
Dry-Mode removes moisture w/o affecting temp
Cross Flow Technology reduces noise output
Easy Maintence - Panel Removes for Access
Freon Leak Detection > Notification system
Low Ambient Heating Temp. Operation
Two-direction Air vane Evenly Distributes Air
Restart IC: Settings restored Following Outage
2 Year Part - 5 Year Compressor Warranty >>> |
|
|
|
|
 |
|
|
|
|
|
Model |
/ |
ABSEM4H4S24/ABSEM4H4S24 |
Power Supply |
Rated Voltage |
V |
208/230 |
Rated Frequency |
Hz |
60 |
Phases |
/ |
1 |
Power Supply Mode |
/ |
Outdoor |
Cooling Capacity (Min~Max) |
BTU/h |
24000 (8000~26500) |
Heating Capacity (Min~Max) |
BTU/h |
24500 (8000~26500) |
Cooling Power Input |
W |
2035 |
Heating Power Input |
W |
2080 |
Cooling Current Input |
A |
9.2 |
Heating Current Input |
A |
9.3 |
Current Range (Cooling) |
A |
1.8-13 |
Current Range (Heating) |
A |
1.8-13 |
Air Circulation |
m3/h |
1200 |
Dehumidifying Volume |
L/h |
2.4 |
EER |
BTU/Wh |
11.73 |
COP |
BTU/Wh |
11.78 |
SEER |
/ |
20.5 |
HSPF |
/ |
11.8 |
Application Area |
ft2 |
290.6-452.25 |
Indoor Unit |
Indoor Unit Model |
/ |
ABSEM4H4S24 |
Fan Type |
/ |
Cross-Flow |
Indoor Motor Speed (H/M/L) |
r/min |
1200/1040/880 |
Fan Motor Power Output |
W |
35 |
Evaporator Form |
/ |
Aluminum Fin-copper tube |
Evaporator Pipe Diameter |
mm |
Φ7 |
Sound Pressure Level (H/M/L/SL) |
dB(A) |
48/45/40/36 |
Net Dimensions (WXHXD) |
inch |
43 5/16 x 12 13/16 x 9 5/8 |
Dimension of Package (WXHXD) |
inch |
46 1/16 x 15 3/8 x 12 7/16 |
Net Weight |
lbs |
31.97 |
Gross Weight |
lbs |
37.48 |
Outdoor Unit |
Outdoor Unit Model |
/ |
ABSCI4H4S12 |
Compressor Manufacturer |
/ |
GMCC or MITSUBISHI |
Compressor Type |
/ |
Rotary |
Throttling Method |
/ |
Capillary |
Set Temperature Range |
°F |
61~86 |
Ambient Temperature (Cooling) |
°F |
5~115 |
Ambient Temperature
(Heating) |
°F |
(-4)~75 |
Condenser Form |
/ |
Aluminum fin-copper tube |
Condenser Pipe Diameter |
mm |
Φ7 |
Condenser Rows-fin Gap |
mm |
1.4 |
Fan Motor Speed (H/M/L) |
RPM |
1200/550/500 |
Output of Fan Motor |
W |
61 |
Fan Type |
/ |
Axial Flow |
Sound Power Level |
dB(A) |
58 |
Defrosting Method |
/ |
Automatic Defrosting |
Dimension (WXHXD) |
inch |
34 7/8 x 31 5/16 x 14 3/8 |
Dimension of Package (L/W/H) |
inch |
41 11/32 x 35 x 19 11/6 |
Net Weight |
lb |
123.46 |
Gross Weight |
lb |
141.1 |
Refrigerant |
/ |
R410A |
Connection Pipe |
Pre-charge Length |
ft |
24.6 |
Outer Diameter Liquid Pipe |
in |
3/8 |
Outer Diameter Gas Pipe |
in |
5/8 |
|
|
|
|
Install Kit Contents: |
- 11 Ft Flared Copper Tubing
- 11 Ft Pipe Insulation
- 12 Ft Electrical Wire - INDOOR>OUTDOOR
- 8 Ft Electrical Wire - OUTDOOR>BOX
- Drain Pipe (indoor)
- Wall Bracket for Indoor Unit
- Plastic Pipe Wrap
- Installation and User Manual
- Neoprene Putty to Seal Holes
|
|
|
 |
 |
|
|
Extend included 11 foot copper lineset to 6/ft contact us for details > |
|
|
|
|
 |
|
WHAT IS DC INVERTER?
DC Inverter Air Conditioners are the ultimate cooling technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.
Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained.
 |
|
|

|
|
|
|
BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with R410A Freon however, procedures such as conducting leak tests etc. are still important steps in ensuring proper functioning system. Click for Service Manual - Click for User Manual. *Although installation may seem easy to some, certain tools and experience is necessary to complete setup of a mini split* Click for Installation Tip. It is highly advised a certified HVAC technician complete installation to be eligible for warranty. See warranty details below > |
|
 |
|
|
 |
|
|
|
|
|
These Mini Split units usually ship via ESTES EXPRESS or a similar freight service and palletized into a single shipment. These units ship out of South Florida and are in transit with 1-2 business days from payment receipt. Depending on where you are geographically located, transit time is usually between 3 and 6 business days. Please provide a contact phone# upon checkout where recipient of order can be reached (to be used for delivery purposes only). SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Only ships to the lower 48 Contiguous United States. |
|
 |
|
|
|
|
*5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and a brand new exchange will be shipped out. Download Warranty Spreadsheet |
|
|
|