System Includes: |
|
|
|
|
|
Indoor Unit - Air Handler
Outdoor Unit - Compressor
Digital Multi-function LCD Remote Control
13 ft. Installation kit - Manuals
1 Year Part, 5 year Compressor Warranty > |
|
|
|
|
|
|
|
 |
Top Line Features: |
21 SEER - 9.5 HSPF - ENERGY STAR
Pre-Charged w/ Eco-friendly R410A Refrigerant
Dry-Mode removes moisture w/o affecting temp
Cross Flow Technology reduces noise output
SILVER ION Filter system for Ultra Hygenic Air
Freon Leak Detection > Notification system
Low Ambient Temperature Operation (5° F)
Two-direction Air vane Evenly Distributes Air
Restart IC: Settings restored Following Outage
1 Year Part - 5 Year Compressor Warranty >>> |
|
|
|
 |
|
|
|
Model Number |
SENA-18HF |
Style |
Ductless Mini Split AC With Heat Pump |
Compressor |
Toshiba (GMCC) |
Refrigerant |
R410A (Pre-Charged)/1900g |
Cooling Capacity |
17500 BTU |
Heating Capacity |
18000 BTU |
Air Flow |
1200/950/750 m3/h |
Power Supply |
208-230 V / 60 Hz, 1Ph |
Input Power |
1400W (cooling) / 1440W (heating) |
Input Current |
6.5A (Cooling) / 6.66A (Heating) |
SEER |
21 |
EER |
3.66 |
HSPF |
9.5 |
Sound Level |
47/40/31 dB (Indoor) / 54dB (Outdoor) |
Moisture Removal |
1.7 L/hr |
Min Operating Temperature |
- 15 C / 5 F |
Control System |
Digital Multifunction infrared Remote control with indoor unit Dynamic digital LED display |
Net Weight |
26.5 Lbs (Indoor)/ 102 Lbs (Outdoor) |
Dimensions |
38.98 x 8.58x 12.40 in (Indoor Unit) 33.27 x 12.60 x 27.56 in (Outdoor Unit) |
Warranty |
1 Year on Parts / 5 Years on Compressor |
|
|
|
|
 |
|
 |
|
WHAT IS DC INVERTER? |
|
DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.
Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained. |
|
|
|
 |
|
 |
|
|
|
Install Kit Contents: |
- 13 Feet Flared Copper Tubing
- 13 Feet Pipe Insulation
- Drain Pipe (outdoor)
- Wall Cross piping
- Binding Belt - Catchment Trough
- Remote Control Wall Bracket
- Wall Hole Block Putty & Insulated Tape
|
|
|
 |
 |
|
|
|
|
|
 |
|
SHIPS TO TO BOTH UNITED STATES AND CANADIAN LOCATIONS! |
|
 |
|
|
Our Mini Split systems ship via YRC FREIGHT or similar on-truck freight service and are palletized onto a single parcel. Transit time is usually between 4 to 7 business days from payment receipt depending on where you are geographically located. Please provide a contact phone# upon checkout (to be used for delivery purposes only). SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Failure to provide valid contact# will delay order.
For U.S. orders, unit will ship out of Gardena, CA. Canadian Orders will ship out of Saint-Leonard, Quebec. |
|
|
 |
|
|
|
|
BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with R410A Freon however, the lines still need to be vacuumed to evacuate the excess Nitrogen prior to the final coupling for operation. *Although the installation may seem easy to some, certain tools and experience is necessary to complete installation of a mini split* Click for Installation Tip. It is highly advised a certified HVAC technician conduct / complete installation to be eligible for warranty. (See warranty details below > ) |
|
 |
|
|
 |
|
|
|
|
|
*5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and a brand new exchange will be shipped out. 1 YEAR PARTS WARRANTY CAN BE EXTENDED TO 2 YEARS FOR AN ADDITIONAL $72.00 |
|
|
  |
Condenser Ground Stand |
|
 |
|
- Provides Flat even surface
- Avoids debris obstruction
Price: $173.00
Click for more Info
|
|
25' Extension kit (1/4 x 3/8) |
|
 |
|
- Extend included 16 ft copper lineset to 25 ft.
Price: $34.00
Click for more Info |
|
Condenser Bracket |
|
 |
|
- Mount your condenser at any height on an outdoor sidewall
Price: $56.00
Click for more Info
|
|
Micro-Pump II |
|
 |
|
- Required when mounting air handler on Interior wall
Price: $132.00
Click for more Info
|
|
|
|
 |
|
|