System Includes: |
|
|
|
|
|
Indoor Unit - Air Handler
Outdoor Unit - Compressor
Digital Multi-function LCD Remote Control
linesets not included
choose lineset using the dropdown
Product and Installation Manual |
|
|
|
|
|
|
|
 |
|
Top Line Features: |
|
Maximum Efficiency: 22 SEER Inverter Technology
Pre-Charged with Eco-friendly R-410a Refrigerant
New sleek 'SILVER' series Design
24,000+ BTU's of Turbo Cooling
Anti-Corrosive treatment in equipment components
Good Sleep Cooling Operation
Signal Reception Indicator - Vertical Auto Swing
Auto & 3-Speed Fan Control with 24 Hour Timer
COOL ONLY SYSTEM - NO HEAT PUMP FUNCTIONS |
|
|
|
|
|
|
 |
|
|
|
 |
|
 |
|
WHAT IS DC INVERTER? |
|
DC Inverter Air Conditioners are the ultimate cooling and heating technology of the HVAC field. They are called "DC inverter" because the alternative current (AC) is converted to Direct Current (DC) then, direct current inverted back to Alternative current with desired frequency. The current supplied through the wall outlet has fixed frequency which is 60 Hertz. Different frequencies supplied to the compressor will result in different running speeds of the compressor. Inverter control systems use Pulse Amplitude Modulation (PAM) that is the most advanced and energy efficient method of inverting the current. DC Inverter AC's bear special compressors that their speed could be changed by increasing or decreasing the frequency of the supplied power. Therefore, unlike conventional split Air Conditioners/Heat Pumps which cycle between on and off repeatedly, the DC Inverter control system will monitor the room temperature and adjust the compressor speed automatically.
Conventional compressors turn on and off to maintain the room temperature at desired level. This will result compressor to draw tremendous energy each time it starts up. This will also reduce the life-span of the compressor and other components that are turning on and off. Once a conventional system is running, it runs at its maximum speed, consuming the maximum amount of energy in order to produce the maximum of cooling or heating to maintain the desired temperature. The system will then cycle between on and off in an effort to maintain this temperature. When a DC Inverter compressor initially starts up, it runs with a higher speed to bring the room temperature to desired level rapidly, Once the set temperature is reached, it slows down and adjust its capacity just to counter the heat loss or heat gain of the building. Constant temperature is maintained. |
|
|
|
 |
|
 |
|
|
|
These Mini Split units usually ship via Southeastern Freight (on truck) and are divided between 3 parcels per system (install kit - condenser - air handler). These units ship out of South Florida and are in transit with 1-2 business days from payment receipt. Depending on where you are geographically located, transit time is usually between 3 and 6 business days. Please provide a contact phone# upon checkout where recipient of order can be reached at. SOMEBODY MUST BE ON SITE TO ACCEPT / SIGN FOR Order. Only ships to the lower 48 Contiguous United States. |
|
 |
|
|
|
|
BASIC OVERVIEW: The indoor unit is hung like a picture frame approximately 6 - 8 feet above the floor usually on an exterior wall. A 2-3 inch hole must be made behind the indoor unit in the exterior wall to run the refrigerant copper tubing, electrical wires and the condensate drain to the outside unit. The indoor unit and outdoor unit are connected to each other by means of refrigerant copper tubing and electrical cables. The condensing unit comes pre-charged with R410A Freon however, the lines still need to be vacuumed to evacuate the excess Nitrogen prior to the final coupling for operation. *Although the installation may seem easy to some, certain tools and experience is necessary to complete installation of a mini split* Click for Installation Tip. It is highly advised a certified HVAC technician conduct / complete installation to be eligible for warranty. (See warranty details below > ) |
|
 |
|
|
 |
|
|
|
|
|
*5 Year Compressor - 1 Year on all other Parts* Registration card will be sent with unit, this card should be completed by an HVAC technician (installer). Installation of a mini split must be completed by a licensed HVAC (Heating, ventilating, & air conditioning) company to ensure any issues encountered in the future are not due to improper installation / workmanship. Even though mini split setup is below the expertise requirements of central AC systems, these are not "plug-n-play" units that can be properly installed without certain tools any prior HVAC - electrical knowledge. The installation includes electrical, gas, and refrigerant connections and generally regulated by a multiple sets of laws, codes and guidelines, at the federal, state and local levels. The failure to properly install HVAC equipment can raise personal safety and performance concerns. Warranty service - troubleshooting is provided through the contractor / installer and will be upheld as long as policies are observed. Once a non-defective unit is installed by a HVAC company, chances of anything going wrong are very slim and almost all contractors will guarantee there workmanship and provide future service free of charge (installation warranty). If it was determined that the unit is not functioning due to a defect and needs to be replaced, the part will be sent free of charge up to 1 year from date of purchase or 5 years for the compressor. If you receive a damaged or defective product, a replacement unit will be sent out Free of cost. Damaged / Defective product will be picked up and a brand new exchange will be shipped out. Download Warranty Spreadsheet |
|
|
|
|
 |
|
|
|